LMTD DERIVATION PDF

DERIVATION OF LMTD FOR COUNTER FLOW HEAT EXCHANGER. Assumptions used. 1. U is constant all along the HEX. 2. Steady flow. Brief Derivation of the LMTD. To design or predict the performance of a heat exchanger, the LMTD and the effectiveness-NTU methods are both. Derivation of Log Mean Temperature Difference (LMTD) for Parallel flow heat exchanger.

Author: Gashura Vogul
Country: Cameroon
Language: English (Spanish)
Genre: Life
Published (Last): 18 March 2011
Pages: 84
PDF File Size: 2.29 Mb
ePub File Size: 20.53 Mb
ISBN: 961-7-56067-386-4
Downloads: 19448
Price: Free* [*Free Regsitration Required]
Uploader: Maukazahn

The LMTD is a logarithmic average of the temperature difference between the hot and cold feeds at each end of the double pipe exchanger. Summed together, this becomes.

Derivation of Log Mean Temperature Difference (Heat Exchanger

Where Q is the exchanged heat duty in wattsDfrivation is the heat transfer coefficient in watts per kelvin per square meter and Ar is the exchange area. That is, the rate of heat loss from the hot fluid at any section of a heat dwrivation is equal to the rate of heat gain by the cold fluid in that section.

Engineering in your pocket Download our mobile app and study on-the-go. Views Read Edit View history.

Derive the expression for derivxtion mean temperature difference LMTD in parallel flow heat exchanger. Use the fact that the heat exchanger area Ar is the pipe length B – A multiplied by the interpipe distance D:. You get question papers, syllabus, subject analysis, answers – all in one app.

Logarithmic mean temperature difference

The total exchanged energy is found by integrating the local heat transfer q from A to B:. We assume that a generic heat exchanger has two ends which we call “A” and “B” at which the hot and cold streams enter or exit on either side; then, the LMTD is defined by the logarithmic mean as follows:. The temperature change of the hot fluid is a negative quantity, and so a negativesign is added to Eq.

  ENEIDA VERGILIUS PDF

Assume heat transfer [1] is occurring in a heat exchanger along an axis zlmtr generic coordinate A to Bbetween two fluids, identified as 1 and 2whose temperatures along z are T 1 z and T 2 z. By using this site, you agree to the Terms of Use and Privacy Policy. Assuming the outer surface derivwtion the heat exchanger to be well insulated so that any heat transfer occurs between the two fluids, and disregarding any changes in kinetic and potential energy, an energy balance on each fluid in a differential section of the heat exchanger can be expressed as Fig: From Wikipedia, the free encyclopedia.

This holds both for cocurrent flow, where the streams enter from the same end, and for counter-current flow, where they enter from different ends. The rate of heat transfer in the differential section of the heat exchanger can also be expressed as.

Download our mobile app and study on-the-go. From first law of thermodynamicsrequires that the rate of heat transfer from the hot fluid be kmtd to the rate of heat transfer to the cold one. With this definition, the LMTD can be used to find the exchanged heat in a heat exchanger:.

Logarithmic mean temperature difference – Wikipedia

For a given heat exchanger with constant area and heat transfer coefficient, the larger the LMTD, the more heat is transferred. Taking values of mCp from above equation and substituting in the integrating solution and solving it. Note that estimating the heat ferivation coefficient may be quite complicated.

The heat that leaves the fluids xerivation a temperature gradient according to Fourier’s law:. Assuming the outer surface of the heat exchanger to be well insulated so that any heat transfer occurs between the two fluids, and disregarding any changes in kinetic and potential energy, an energy balance on each fluid in a differential section of the heat exchanger can be expressed as.

  ARMV5TEJ INSTRUCTION SET PDF

LMTD -Counter Flow Heat Exchanger – ME Subjects – Concepts Simplified

Is the log mean temperature difference, which is the suitable form of the average temperature difference for use in the analysis of heat exchangers.

The temperature change of the hot fluid is a negative quantity, and so a negativesign is added to. Variation of the fluid temperatures in a parallel-flow double-pipe heat exchanger. This page was last edited on 23 Decemberat Retrieved from ” https: The use of the LMTD arises straightforwardly from the analysis of a heat exchanger with constant flow rate and fluid thermal properties.

A correction factor is also required for other more complex geometries, such as a shell and tube exchanger with baffles. The logarithmic mean temperature difference also known as log mean temperature difference or simply by its initialism LMTD is used to determine the temperature driving force for heat transfer in flow systems, most notably in heat exchangers.

In a cross-flow, in which one system, lmtr the heat sink, has the same nominal temperature at all points on the heat transfer surface, a similar relation between exchanged heat and LMTD holds, but with a correction factor.