The from Keithley is a 20 channel differential multiplexer with automatic CJC. The CJC sensor is mounted on the multiplexer module’s PC board and it. Buy Keithley Digital Multimeter for RTD, Thermistor, Thermocouple Browse our latest data-acquisition-accessories offers. Free Next Day Delivery. Keithley Ch Differential Multiplexer Module w/Auto CJC/Screw Terminals for , , – at the Test Equipment Depot.

Author: Kigabar Tojat
Country: Liechtenstein
Language: English (Spanish)
Genre: History
Published (Last): 19 October 2006
Pages: 103
PDF File Size: 13.35 Mb
ePub File Size: 4.4 Mb
ISBN: 226-7-62923-230-7
Downloads: 45972
Price: Free* [*Free Regsitration Required]
Uploader: Tojajas

Providing the finest test equipment solutions since 1992

You can control up to eight instruments at the same time and retrieve millions of readings from each instrument. Also save test time by reducing communication with the test controller.

The Series plug-in module offers 20 channels of 2-pole or 10 channels of 4-pole multiplexer switching that can be configured as two independent banks of multiplexers.

A large 5-inch View Cart My Account That is the minimum set of parameters needed to run a test. This allows you to create powerful measurement applications without an integrated development environment IDE.

There are two additional protected channels for current measurements. The Keithley DAQ can be operated from the front panel while a test is in progress. Program statements control script execution and provide facilities such as variables, functions, branching, and loop control.

Do all this from two menus and see – on one screen – how each channel is keithleh. Measure up to 80 devices with two switch modules. For example, measure the temperature of devices in an environmental chamber with thermocouples using the plug-in switch modules that have automatic cold reference junction compensation for thermocouple measurements.

Using the TSP language to create a script, the user can display messages for an operator in an automated or a semi-automated test system. If main power is lost, the Keithley DAQ will re-start the scan when the power is restored. Thus, when relay switch closures approach the manufacturers’ relay life specification, the switch card module can be replaced during scheduled maintenance.

  BABOK PORTUGUES PDF

TSPLink technology supports up to 32 instruments, so it’s easy to scale a system to fit the requirements of an application. Use the scan status, swipe screen to continuously monitor channels. There are additional optional parameters to adjust the keirhley and the switching to meet a specific application.

The Keithley DAQ Data Acquisition and Logging Multimeter System is a precision data acquisition and logging system that creates a new level of simplicity compared with the often complicated configuration and control found in many stand-alone solutions. Of most importance, there is no lost test time due to the instrument sitting idle following a power outage. Automatic CJC is provided so that no other accessories are required to make thermocouple temperature measurements.

TSP scripting allows running powerful test scripts directly on the instrument, without the need for an external PC controller. In fact, the DAQ can execute an automated sequence entirely without a PC thus saving test time and reducing the capital cost of the system. In addition, two modules have current measurement channels.

Save bench space and cost with an instrument that performs like a DMM and a data logger. The low frequency, keitgley pole switch modules can allow measurement of voltage, 2-wire- and 4-wire resistance, and frequency. To test channels during setup, manually close channels on the setup screen. Test scripts can contain kithley sequence of routines that are executable by conventional programming languages including decision-making algorithmsso the instrument can manage every facet of the test without the need to communicate with a PC for decision making.

Used Keithley Instruments 20 Channel Multiplexer Card | MATsolutions

Thus, for most applications, the calibration cycle for the DAQ can be two years. Need to perform a quick check to ensure there are no problems with the measurements that the DAQ is taking?

  LEXMARK 2591 N PDF

This makes KickStart a great solution for your datalogging needs and for capturing lots of data from transient events with a digitizing DMM. The DAQ has the built-in intelligence to execute a test script, make decisions, and control other instruments. Build a test sequence and define the required measurements from one setup screen. The keithlej data will be stored in a separate keitjley buffer with time-stamped measured data so that the lost time due to the power failure can be noted.

Also select a control module and two RF modules with 2 GHz and 3. The Status screen ksithley display an out-of-limit indication when any channel’s measurement is outside the channel’s limit settings.

Data can be stored to an external USB memory stick to prevent data loss in the event of interruption of line power. For maximum accuracy, measurements can be filtered and integrated over a range of time intervals.

This channel expansion bus allows connecting multiple DMM’s, other TSP-enabled instruments, and any LAN-based instruments together to form a tightly-synchronized instrument system. Getting insights quickly is important, so KickStart plots your data immediately and dedicates a large 7070 of the viewing area to the graph, while also allowing you to view and edit the most essential parameters of other instruments in your test setup. The dual functionality enables maximized utilization of your instrument.

Make your measurements with instrument-grade quality. Even switch signals from wireless devices with RF modules having a maximum switching frequency of 3.

Use the DAQ with its front panel terminals to troubleshoot a test setup, a circuit, or to verify the value of a component. The system is organized in a master-subordinate configuration, essentially allowing the connected instruments to act as one.