APC AP7752 PDF

Buy APC AP Rack ATS/20A/Outlet/V Rack-mount Transfer Switches: Switches – ✓ FREE DELIVERY possible on eligible purchases. AP APC by Schneider Electric UPS – Uninterruptible Power Supplies Rack ATS, V, 20A, L in, (10) R out datasheet, inventory, & pricing. The APC AP is a Rack-mount Transfer Switches, Input: V, Input Connections: NEMA LP, Cord Length: 8 feet ( meters), Output: V.

Author: Dogore Arashile
Country: Sri Lanka
Language: English (Spanish)
Genre: Politics
Published (Last): 15 October 2004
Pages: 418
PDF File Size: 14.9 Mb
ePub File Size: 19.30 Mb
ISBN: 968-8-62797-174-3
Downloads: 24254
Price: Free* [*Free Regsitration Required]
Uploader: Zulumi

APC offers units that bring up to Energy Efficiency Data Center Operation: Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Product family includes a variety of input and output connections to distribute Spc, V, or V power to multiple outlets.

Two AC lines power the unit and if the primary AC power fails, the unit will automatically switch to the alternative power source. Provides redundant rack mount power to single-corded equipment.

  DARK SOUL 2 ALEKSANDR VOINOV PDF

Wide range of input and output connections. The aggregate current draw per rack PDU is displayed on the unit via a digital display.

APC RACK ATS, 120V, 20A, L5-20 IN, (10) 5-20R OUT (AP7752)

Dual Input Power Sources. Order Status Order Status. Capacity Data Center Operation: Supplies redundant AC power to connected equipment. Having a variety of inputs and outputs allow users to adapt to varying power requirements. Provides protection in the event of a significant aap7752 event.

RACK ATS, V, 20A, L IN, (10) R OUT – APC USA

This allows the user to zpc glance at the power flow and status of the input sources without connecting to the unit.

Available on designated SKUs only. Indicates the status of the AC sources powering the units, as well as indicates which source is set as the primary source and which source is currently supplying power to the load.

Puts the power where it is needed most – in the rack near the equipment. Call for More Information Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. This provides a visual depiction of the power appc from the input to the load.

  ALEISTER CROWLEY WHITE STAINS PDF

RACK ATS, V, 20A, L IN, (10) R OUT – APC Canada

Provides more robust and intuitive local control and manageability. This product is discontinued.

The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. Occupys only 1U of valuable rack space. Transfer time Industry leading transfer time to ensure seamless ride through in the event of a primary power source failure. Change Data Center Operation: Cooling Optimize Data Center Operation: